Home > Error Code > Balboa Hl Error Code

Balboa Hl Error Code

Contents

ICE = Freeze condition. 55°F detected. No action is necessary.I CE2 = Freeze protection. CTI Spa Side Error Codes th1/39 = On startup indicates temperature probe problem. Press "Mode" Button to Clear Message. http://gatoisland.com/error-code/balboa-error-code-oh.php

Any suggestions? All started as usual. 2 hours later I noticed it had turned off and it was displaying a OH error. Pump may also be deactivated). You can skip Priming Mode if you're restarting the spa for some other reason (without the water having been drained since the last time the spa functioned properly).

Balboa Sns Error Code

Turned off at the main breaker it came back on.. Heater is deactivated. The fundamental reason is water flow through the spa control system, if the water is not flowing at a rate to satisfy the switch, it will result in one of the Note: A common programming mistake is overlapping filter times that may cause the spa to filter continuously.• Check the water level.• Check the water temperature with an accurate temperature thermometer.

  • Dirty Filter.5.
  • Select "Message Other than rtC or RTC FAILURE" Below.
  • The equipment stays on until the sensors detect that the spa temperature has risen to within 20 degrees of the set temperature.
  • Got new cover gave a clean, filled the tub and powered on..

PSoL = Pressure switch open with low pump. Power on the spa must be cycled before the heater will function again. Why does the system power input fuse (20A, 25A or 30A) keep blowing? Balboa High Limit Switch Location OH = Overheating, water over 112° F.

The tub temp actually dropped 5 degrees today. System will restart when temp. However he had pretty much replaced the board by then so didn't want to swap all back just to test. After the heater is energized, the temp sensor on the exiting side may read slightly warmer, depending on pump flow.

Select "Message Other than PSt or PERSIST FAIL" Below. Balboa Hot Tub Error Codes Share this post Link to post Share on other sites christiffa25 0 Junior Member Members 0 38 posts Posted May 1, 2012 · Report post Ok swine, i dont have Then re-start the hot tub, if the error code goes away, the problem was either a dirty filter (clean or replace) or too many jets were closed off. Do you know if the readings I got off the ohm tester listed at top of page seem right?

Arctic Spa Hl Error Code

Touch any button to reset the system. It could be a loose plug connection or bad wire, or it could be a problem related to water flow. Balboa Sns Error Code If there is Now an Error Message, select Message Other than CrC or CHKSUM FAIL below.No Error Messages3. Hl Error Code Hot Tub Product Technical Support Help Me Replace A Part Product Manuals Product Color Codes Spa Panel Messages Topside Panel Manuals Common Spa Problems System Cross Reference Home>Balboa Spa Panel Messages Balboa Common

Blocked Skimmer.4. http://gatoisland.com/error-code/099-error-code.php There was no corrosion. Contrary to popular belief, these sensors themselves RARELY "go" bad. After about 45 Seconds, Check for Error Messages on the Topside Panel Display. Balboa High Limit Sensor

If the flow rate still seems less than normal with all jets and valves open, you may consider inspecting for broken valves (closed when they appear to be open), clogged impeller Status of the heater element is unknown. Contact your Dealer or Service Organization.A Sensor Failure Message may indicate Excessively High Heater Temperatures which can Scald or Burn!If the Heater is Not Cool Enough to Safely Service, allow the this contact form To read the Current Water Temperature, either Change to Standard Heating Mode or turn On the Heating Related Pump, and wait at least 2 Minutes. 'Sn' Sensors are out of

Starting to run out of ideas with this tub!! Balboa Spa Control Manual dr = Inadequate water detected in heater. Note: Internal freeze protection only functions when there is proper power running to the spa, and the control system is operational.

Heater disabled but the spa is operational.

Basically what I'm asking is do you wise people think I can rule out hi-limit and temp sensor being the problem given the readings I got? Back to Top rCL or CLEAN FILTER Message Time to "Clean Filter Reminder" (rCL).Appears Every 30 Days*. Contact qualified service technician. Balboa Hot Tub Codes Sl A few more hours and I should see clearly Logged Water Boy Full Member Posts: 627 Re: HL reading « Reply #10 on: January 03, 2009, 07:06:12 PM » Bosco,I agree

this information is being provided for informational purposes only. Remove, Clean, and Reinstall Spa Filter Cartridge per Manufacturers Instructions. Press "Mode" Button to Clear Message. http://gatoisland.com/error-code/005-122-error-code.php Why does the GFCI trip immediately upon power up?

Brett Aqualine OH = Temp exceeds 118° F Fr = Freeze condition - temp below 40° F FL = Pressure switch failure EO = Shorted temp sensor E1 = Open temp The start-up numbers are insignificant, and it sounds like you briefly entered the filtration programing (F2) before the spa locked you out and shut down due to the "OH" condition. System will restart when temp. If HL comes on when it gets to hot then something may infact be wrong.

© Copyright 2017 gatoisland.com. All rights reserved.