Home > Error Code > Balboa Error Code Oh

Balboa Error Code Oh

Contents

Where as mine just flashes oh immediately making troubleshooting very hard?? Entire system is disabled. PSoH = Pressure switch open with high pump. Balboa (used by Belize Spas and many other hot tubs) pd = Power supply, unit running on battery backup OH = Sensors reading 112-118° F. have a peek here

Powered by vBulletin Copyright © 2016 vBulletin Solutions, Inc. Spa Guy 796 views 1:18 Balboa Legacy Systems Series - Troubleshooting Panel Messages Sn1, Sn3, Sn or Heat Status LED - Duration: 2:47. This feature is not available right now. does the pump come on and move the water well?

Balboa Sns Error Code

Blocked Suction Fitting.3. Heater is deactivated. Below is a list of common error codes from the top manufacturers of control equipment for hot tubs. Who do I call if my panel or system isn't working?

Note: Internal freeze protection only functions when there is proper power running to the spa, and the control system is operational. Everything has been working ok but we have had a leak that I couldn't at first locate. This is an indication of a pressure switch stuck in the closed position. Balboa Vs500 Error Codes This indicates a Possible Problem with The System Board.

Sundance Spa or Hot Tub Control Systems: ILOC = Interlock failure - possible pump or ozone spike FLO = Pressure switch malfunction or Flow switch malfunction (system specific)Hold = Panel buttons Check voltage across the two connections to the heater. Pictured here is a Balboa® control system used in Belize Spas brand. Make sure the pressure switch wire is connected to the proper circuit board connector.

If there is Now an Error Message, select Message Other than PSt or Persist Fail below.No Error Messages3. Balboa Fault Codes Back to Top gFI or GFCI FAILURE Message The Control System Could Not Trip the "GFCI" (gFI).The spa has determined that a GFCI is NOT properly installed in the circuit providing Steve Cape Coral, FL 2003 Jacuzzi Premium J350 w/ozonator & cover Reply With Quote 07-02-2012,06:10 PM #18 09lancer View Profile View Forum Posts View Articles Join Date Jun 2010 Posts The fundamental reason is water flow through the spa control system, if the water is not flowing at a rate to satisfy the switch, it will result in one of the

  • drops.
  • Oh Error On Balboa System Theme Default (Default) Copy of Default Contact Us PoolSpaForum.com Community Software by Invision Power Services, Inc. × Existing user?
  • Check for proper spa water level and ensure pump is primed.

Balboa Error Codes Hot Tubs

The following is a list of most probable causes of this message. I may be wrong??? Balboa Sns Error Code Purchased both a temp sensor and hi limit sensor and replaced them both. Balboa Spa Error Codes When I reset the breaker & turn it on then it immediately trips once again.

The "SF" Safety Fault Error Message indicates that the Vacuum Switch has closed, indicating that there has been a Suction Problem or a Possible Entrapment Situation Avoided.2. http://gatoisland.com/error-code/099-error-code.php Advanced Search Forum > Swimming Pool Care > Spas and Hot Tubs > OH error code Welcome to Trouble Free Pool We would like to welcome you to TFP, the webs Do not enter the water. If it still displays "SN3" then replace the board. Balboa Vs501z Error Codes

Sign in Transcript Statistics 13,296 views 10 Like this video? Contact your Dealer or Service Organization. If there is Now a "CrC" or "CHKSUM FAIL" Error Message, contact your Dealer or Service Organization. Check This Out Blocked Suction Fitting.3.

Doing this will give you full access to the forums, where you will be able to receive personalized advice concerning your pool. Balboa Hot Tub Heater Troubleshooting Try reversing them- plug the sensor harness into the high limit receptacle, and vice versa. ICE2 = Freeze protection.

This turns on pump 1, and also turns on the circ pump.- Verify that both pump 1 and the circ pump are running and that water is flowing out of both

Clean and Condition Spa Cover per Manufacturers Instructions. Turn OFF the Power to the System and Turn it back ON again to put System into Priming Mode.2. Make sure the system has proper incoming voltage. Balboa Hot Tub Codes Pressure switch is not working.SN = Non functional high temperature sensor.

FL = Flow. Plug in a new transformer. There is Not enough Water in the Heater to Start it. http://gatoisland.com/error-code/005-122-error-code.php Open the spa cover to allow excess heat and steam to escape.

Back to Top Ecn or Ec Message Ecn or Ec MessageIf the Ecn or Ec Message is Alternating with the Water Temperature on the Display, the Spa is Operating in the There was no corrosion. Turn OFF the Power to the System and Turn it back ON again to put System into Priming Mode.2. No Automatic Functions will turn ON during this time, and the Heater will Not Start.

Blocked Suction Fitting.3. I pulled the side panels off & don´t see any leaks, the floor around it isn´t wet, etc. For information on reproducing our logo and any product images found on this website, contact the Marketing Department. Pentair CCP420 Cartridge Filter Pentair Inteli-flow VS Pump Hayward Goldline SWG Tigershark QC Robot Reply With Quote 04-21-2012,11:44 AM #16 jpg11124 View Profile View Forum Posts View Articles Join Date

ICE = Freeze condition. 55ºF detected. It's easy! I think it is a temp sensor. PSoC = Pressure switch open with circulating pump.

Do not do this more than 5 times. Locate the dip switch on the dip switch bank that's labled "test mode," and enable it.

© Copyright 2017 gatoisland.com. All rights reserved.